Camshaft Runout
SPECIAL TOOL(S)
| Dial Indicator Gauge With Holding Fixture 100-002 TOOL-4201-C |
General Procedure
NOTE:
Refer to general specifications in the appropriate Engine article for the appropriate specification.
NOTE:
Camshaft journals must be within specifications before checking runout.
- 1.
Using the Dial Indicator Gauge with Holding Fixture, measure the camshaft runout.- Rotate the camshaft and subtract the lowest Dial Indicator Gauge reading from the highest Dial Indicator Gauge reading.