Catalyst Monitor Sensor - 3.5L Ti-VCT: Installation
- 2.
Using the Exhaust Gas Oxygen Sensor Socket, install the CMS.- Tighten to 48 Nm (35 lb-ft).
NOTE:
The correct torque wrench setting must be calculated when using the Exhaust Gas Oxygen Sensor Socket to install the CMS. REFER to Service Information
.