Home >> Ford >> 2015 >> Explorer Limited, 3.5L Eng VIN 8, AWD >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control - EMTC >> Diagnosis And Testing >> Climate Control System >> Pinpoint Tests >> PINPOINT TEST H : The Air Inlet Door Is Inoperative >> Notes

PINPOINT TEST H : The Air Inlet Door Is Inoperative: Notes

Refer to MANUAL CLIMATE CONTROL SYSTEM for schematic and connector information.

Normal Operation and Fault Conditions 

Refer to CLIMATE CONTROL - EMTC , Air inlet Mode Door Actuator.

To rotate the air inlet mode door actuator, the HVAC module supplies voltage and ground to the air inlet mode door actuator through the door actuator motor circuits. To reverse the air inlet mode door actuator rotation, the HVAC module reverses the voltage and ground circuits.

The air inlet mode door actuator feedback resistors are supplied a ground from the HVAC module by the air inlet mode door actuator return circuits and a 5-volt reference voltage on the air inlet mode door actuator reference circuits. The HVAC module reads the voltage on the air inlet mode door actuator feedback circuits to determine the air inlet mode door actuator position by the position of the actuator feedback resistor wiper arm.

During an actuator calibration cycle, the HVAC module drives the air inlet mode door until the door reaches both internal stops in the HVAC case. If the air inlet mode door is temporarily obstructed or binding during a calibration cycle, the HVAC module may interpret this as the actual end of travel for the door. When this condition occurs and the HVAC module commands the actuator to its end of travel, the air intake may not be from the expected source.

DTC Fault Trigger Conditions 

DTC Description Fault Trigger Conditions
B1083:11 Recirculation Damper Motor: Circuit Short to Ground This CMDTC sets when the HVAC module senses a short to ground on an actuator motor circuit.
B1083:12 Recirculation Damper Motor: Circuit Short to Battery This CMDTC and on-demand DTC sets when the HVAC module senses a short to voltage on the actuator motor circuit.
B1083:13 Recirculation Damper Motor: Circuit Open This CMDTC and on-demand DTC sets when the HVAC module senses an open on the actuator motor circuit.
B11F0:11 Air Intake Damper Position Sensor: Circuit Short to Ground This CMDTC sets when the HVAC module senses less than expected voltage on the actuator feedback circuit, indicating a short to ground.
B11F0:15 Air Intake Damper Position Sensor: Circuit Short to Battery or Open This CMDTC sets when the HVAC module senses greater than expected voltage on the actuator feedback circuit, indicating an open circuit or a short to voltage.

Possible Sources