Pinpoint Test X : B1A69:11, B1A69:15
- X1 CHECK FOR HVAC MODULE DTCs
- Ignition ON.
- Using a scan tool, perform a HVAC module self-test.
Are DTCs C1B14:11 or C1B14:12 present?
Yes GO to Pinpoint Test C . No GO to X2. - X2 CHECK FOR VOLTAGE TO THE IN-VEHICLE TEMPERATURE AND HUMIDITY SENSOR
- Ignition OFF.
- Disconnect: In-Vehicle Temperature and Humidity Sensor.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C2247-3 Ground
Is the voltage between 4.7 and 5 volts?
Yes For DTC B1A69:11, GO to X3. For DTC B1A69:15, GO to X4. No REPAIR the circuit. - X3 CHECK THE HUMIDITY SIGNAL CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: HVAC Module C228A
- Measure:
Positive Lead Measurement / Action Negative Lead C2247-4 Ground
Is the resistance greater than 10, 000 ohms?
Yes GO to X6. No REPAIR the circuit. - X4 CHECK THE HUMIDITY SIGNAL CIRCUIT FOR AN OPEN CIRCUIT
- Ignition OFF.
- Disconnect: HVAC Module C228B.
Is the resistance less than 3 ohms?
Yes GO to X5. No REPAIR the circuit. - X5 CHECK THE HUMIDITY SIGNAL CIRCUIT FOR A SHORT TO POWER
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C2247-4 Ground
Is any voltage present?
Yes REPAIR the circuit. No GO to X6. - X6 ISOLATE THE IN-VEHICLE TEMPERATURE AND HUMIDITY SENSOR
- Ignition OFF.
- Connect: HVAC Module C228A.
- Connect: HVAC Module C228B.
- Install a new in-vehicle temperature and humidity sensor. REFER to Climate Control - DATC .
- Ignition ON.
- Using a scan tool, perform a HVAC module self-test.
Does the DTC return?
Yes GO to X7. No The cause of the concern was an inoperative in-vehicle temperature and humidity sensor. - X7 CHECK FOR CORRECT HVAC MODULE OPERATION
- Ignition OFF.
- Disconnect and inspect all HVAC module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the HVAC module connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new HVAC module. Refer to Heating Ventilation Air Conditioning (HVAC) Module . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.