Air Conditioning (A/C) Compressor External Leak Test
Component Test
- 1.
Install the adapter from the A/C Flush Adapter Kit on the port of the A/C compressor, using the existing manifold retaining bolt.
- 2.
Connect the high and low pressure lines of a manifold gauge set or a refrigerant recovery/recycling station to the corresponding fittings on the adapter.
- 3.
Attach the center hose of a manifold gauge set to a refrigerant container standing in an upright position.