Symptom Chart: Seating - Memory
Diagnostics in this article assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to SERVICE INFORMATION for information regarding Ford-specific diagnostic practices.
Symptom Chart: Seating - Memory
| Condition | Possible Sources | Actions |
|---|---|---|
| No communication with the DSM | Fuse Wiring, terminals or connectors DSM |
Refer to article 'Module Communications Network', Go to PINPOINT TEST O : THE DSM DOES NOT RESPOND TO THE SCAN TOOL . |
| The power seat moves but is noisy (squeals) when moving the seat horizontally | Front seat motor cable | INSTALL a new front seat motor cable. REFER to Front Seat Motor Cable . |
| The memory seat is inoperative, does not operate correctly - does not operate horizontally, vertically or recline | Fuse Wiring, terminals or connectors Seat control switch Horizontal seat track motor Memory seat track assembly DSM |
GO to PINPOINT TEST I : The Memory Seat is Inoperative or Does Not Operate Correctly - Does Not Operate Horizontally, Vertically or Recline . |
| The memory seat does not operate correctly - does not operate using the memory set switch | Wiring, terminals or connectors Memory set switch Missing status information - MS-CAN Horizontal seat track motor Memory seat track assembly DSM |
GO to PINPOINT TEST J : The Memory Seat Does Not Operate Correctly - Does Not Operate Using the Memory Set Switch . |
| The memory seat does not operate correctly - the seat moves in one-second intervals | Wiring, terminals or connectors Horizontal seat track motor Memory seat track assembly DSM |
CARRY OUT the DSM self-test and retrieve any DTCs. Refer to Seating . |
| The memory seat does not operate correctly - the seat does not move to the correct memory position | Wiring, terminals or connectors Memory set switch Horizontal seat track motor Memory seat track assembly DSM |
CARRY OUT the DSM self-test and retrieve any DTCs. Refer to Seating . |
| The memory seat does not operate correctly - does not operate using the RKE feature | Intelligent Access (IA) key is not correctly associated to a memory position Wiring, terminals or connectors DSM BCM |
VERIFY the RKE feature is operating correctly and is associated to a memory position. REFER to the Owner's Literature, REFER to Handles, Locks, Latches and Entry Systems With Intelligent Access (IA) REMOTE MEMORY ACTIVATION (With Intelligent Access). CARRY OUT the DSM self-test and Refer to Seating . |
| Easy entry/easy exit is inoperative, does not operate correctly | Easy entry/exit feature is not enabled Wiring, terminals or connectors Missing status information - MS-CAN Key-in-ignition switch DSM |
GO to PINPOINT TEST K : Easy Entry, Easy Exit is Inoperative or Does Not Operate Correctly . |