PINPOINT TEST B : The Auxiliary Blower Motor Does Not Operate Correctly
- B1 CHECK THE HVAC MODULE FOR DTCs
- Ignition ON.
- Using a scan tool, perform the HVAC module self-test.
Is DTC B10BA:12 present?
Yes GO to B5. No GO to B2. - B2 CHECK THE AUXILIARY BLOWER MOTOR RELAY COIL SWITCH GROUND CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: Auxiliary Blower Motor Relay.
- Disconnect: HVAC Module C228B.
- Measure:
Positive Lead Measurement / Action Negative Lead Auxiliary Blower Motor Relay Socket Pin 2 Ground
Is the resistance greater than 10, 000 ohms?
Yes GO to B3. No REPAIR the circuit. - B3 CHECK THE AUXILIARY BLOWER MOTOR VOLTAGE CIRCUIT FOR A SHORT TO VOLTAGE
- Disconnect: Auxiliary Blower Motor Speed Control.
- Disconnect: Auxiliary Blower Motor.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C3021-2 Ground
Is any voltage present?
Yes REPAIR the circuit. No GO to B4. - B4 CHECK THE AUXILIARY BLOWER MOTOR GROUND CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C3021-1 Ground
Is the resistance greater than 10, 000 ohms?
Yes GO to B5. No REPAIR the circuit. - B5 CHECK THE AUXILIARY BLOWER MOTOR SPEED CONTROL COMMAND CIRCUIT FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: HVAC Module C228B.
- Disconnect: Auxiliary Blower Motor Speed Control.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C3002-5 Ground
Is any voltage present?
Yes REPAIR the circuit. No GO to B6. - B6 CHECK THE AUXILIARY BLOWER MOTOR SPEED CONTROL
- Install a known good auxiliary blower motor speed controller.
- Reconnect all disconnected connectors. Make sure they seat and latch correctly.
- Ignition ON.
- Operate the auxiliary blower motor.
Does the auxiliary blower motor function correctly?
Yes INSTALL a new auxiliary blower motor speed control. Refer to Auxiliary Blower Motor Speed Control . No GO to B7. - B7 CHECK FOR CORRECT HVAC MODULE OPERATION
- Ignition OFF.
- Disconnect and inspect all HVAC module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the HVAC module connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new HVAC module. For EMTC, REFER to Climate Control - EMTC . For DAMB, REFER to Climate Control - DATC . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.