PINPOINT TEST AD : The Reversing Lamps Are On Continuously: Notes
Diagnostic Overview
The Reversing Lamps Are On Continuously
Refer to Reversing Lamps for schematic and connector information.
Normal Operation and Fault Conditions
Refer to Reversing Lamps , Reversing Lamps - Automatic Transaxle.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1277:15 | Reverse Lamp: Circuit Short To Battery or Open | Sets when the BCM detects a short to voltage from the reversing lamp output circuit. |