LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2015 >> Explorer Limited, 3.5L Eng VIN 8, AWD >> Repair and Diagnosis >> Body & Frame >> Windows >> Window Glass, Window Frames And Window Mechanisms >> Diagnosis And Testing >> Glass, Frames and Mechanisms >> Pinpoint Tests >> PINPOINT TEST R : The One-Touch Up Feature is Inoperative - XLT or Limited >> PINPOINT TEST R : The One-Touch Up Feature is Inoperative - XLT or Limited

PINPOINT TEST R : The One-Touch Up Feature is Inoperative - XLT or Limited

  1. R1 CHECK FOR POWER (B+) LOSS DURING WINDOW OPERATION

    • Verify if power (B+) was lost during window operation.

    Was power (B+) lost while the window was in operation? 

    Yes  RAISE the suspect window to the fully closed position. VERIFY the window glass stalls into the upper header seal for 2 seconds and release the switch. LOWER the suspect window to the fully open position. VERIFY the window glass stalls at bottom of travel for 2 seconds and release the switch. The window should function normally.
    No  For LH front window, GO to  R2. For RH front window, GO to  R4.
  2. R2 INITIALIZE THE WINDOW MOTOR

    Is the one-touch up/down feature operating correctly? 

    Yes  The system is operating normally at this time. The window motor lost initialization.
    No  GO to  R3.
  3. R3 CHECK THE LH FRONT WINDOW CONTROL SWITCH OPERATION AT THE WINDOW MOTOR

    • Ignition OFF.
    • Disconnect: LH Front Window Motor C524 .
    • Ignition ON.
      NOTE: Voltage should be present on both circuits in each of the tested switch positions.
    • While pressing and holding the LH front window control switch in both the UP and DOWN positions, measure:
      Positive Lead Measurement / Action Negative Lead
      C524-4
      GFD33595Courtesy of FORD MOTOR COMPANY
      Ground
      C524-5
      GFD33595Courtesy of FORD MOTOR COMPANY
      Ground

    Are the voltages greater than 11 volts when the window control switch is fully pressed in UP and DOWN positions? 

    Yes  INSTALL a new window regulator motor. Refer to Window Regulator Motor - Front Door . INITIALIZE the window motor. Refer to Window Motor Initialization .
    No  INSTALL a new LH front window control switch. Refer to Window Control Switch .
  4. R4 INITIALIZE THE WINDOW MOTOR

    • Verify the RH window operation from the LH and RH front window control switches.

    Does the one-touch up/down feature operate from both the LH and RH front window control switches? 

    Yes  The system is operating normally at this time. The window motor lost initialization.
    No  If the one-touch up/down feature is inoperative from only one switch, INSTALL a new window control switch. Refer to Window Control Switch . If the one-touch up/down feature is inoperative from both switches, INSTALL a new window regulator motor. Refer to Window Regulator Motor - Front Door . INITIALIZE the window motor. Refer to Window Motor Initialization .