PINPOINT TEST O : One Or More Demand Lamps Are Inoperative
- O1 CHECK THE COURTESY LAMP OPERATION
- Open the left front door and observe the interior courtesy lamps.
Do the interior courtesy lamps illuminate?
Yes GO to O2. No GO to Pinpoint Test F . - O2 CHECK ALL THE DEMAND LAMPS
- Check the operation of all the demand (map and vanity mirror) lamps.
Are all the demand lamps inoperative?
Yes VERIFY the BCM fuse 4 (10A) is OK. If OK, GO to O3. No For a vanity mirror or glove compartment lamp, GO to O4. For a map/reading lamp, GO to O6. For a task lamp (police package only), GO to O8. - O3 BYPASS THE BCM
- Disconnect: BCM C2280D.
- Connect:
Positive Lead Measurement / Action Negative Lead C2280D-22 Positive Battery Terminal
- Switch any demand (map or vanity mirror) lamp on.
Does the demand lamp illuminate when switched on?
Yes REMOVE the jumper wire. GO to O10. No REMOVE the jumper wire. REPAIR the demand lamp voltage supply circuit for an open. - O4 CHECK FOR VOLTAGE TO THE INOPERATIVE LAMP
- Ignition OFF.
- Disconnect: Inoperative Lamp.
- Ignition ON.
- For a vanity mirror lamp, measure:
Positive Lead Measurement / Action Negative Lead Inoperative Left Vanity Mirror Lamp C907-1 Ground Inoperative Right Vanity Mirror Lamp C906-1 Ground
- For the glove compartment lamp, measure:
Positive Lead Measurement / Action Negative Lead C254-1 Ground
Is the voltage greater than 11 volts?
Yes GO to O5. No REPAIR the demand lamp voltage supply circuit for an open. - O5 CHECK THE LAMP GROUND CIRCUIT FOR AN OPEN
- For a vanity mirror lamp, measure:
Positive Lead Measurement / Action Negative Lead Inoperative Left Vanity Mirror Lamp C907-1 Inoperative Left/Right Vanity Mirror Lamp C907-2 Inoperative Right Vanity Mirror Lamp C906-1 Inoperative Left/Right Vanity Mirror Lamp C906-2
- For the glove compartment lamp, measure:
Positive Lead Measurement / Action Negative Lead C254-1 C254-2
Is the voltage greater than 11 volts?
Yes INSTALL a new lamp for the lamp in question. No REPAIR the ground circuit in question. - For a vanity mirror lamp, measure:
- O6 CHECK FOR VOLTAGE TO THE INOPERATIVE MAP/READING LAMP
- Ignition OFF.
- Disconnect: Inoperative Lamp.
- Ignition ON.
- For a front map/reading lamp (overhead console), measure:
Positive Lead Measurement / Action Negative Lead C930-3 Ground
- For a rear map/reading lamp (with roof opening panel), measure:
Positive Lead Measurement / Action Negative Lead Inoperative Left Rear Lamp C941-3 Ground Inoperative Right Rear Lamp C942-3 Ground
- For a rear map/reading lamp (without roof opening panel) or cargo lamp, measure:
Positive Lead Measurement / Action Negative Lead Inoperative Cargo Lamp C927-4 Ground Inoperative Rear Lamp C901-4 Ground
Is the voltage greater than 11 volts?
Yes GO to O7. No REPAIR the demand lamp voltage supply circuit for an open. - O7 CHECK THE MAP/READING LAMP GROUND CIRCUIT FOR AN OPEN
- For a front interior lamp (overhead console), measure:
Positive Lead Measurement / Action Negative Lead C930-2 C930-1
- For a rear interior lamp (with roof opening panel), measure:
Positive Lead Measurement / Action Negative Lead Inoperative Left Rear Lamp C941-1 Inoperative Left Rear Lamp C941-2 Inoperative Right Rear Lamp C942-1 Inoperative Right Rear Lamp C942-2
- For a rear interior lamp (without roof opening panel) or cargo lamp, measure:
Positive Lead Measurement / Action Negative Lead Inoperative Cargo Lamp C927-3 Inoperative Cargo Lamp C927-5 Inoperative Rear Lamp C901-3 Inoperative Rear Lamp C901-5
Is the voltage greater than 11 volts?
Yes INSTALL a new interior lamp for the lamp in question. Refer to Interior Lamp - First Row , Refer to Interior Lamp - Second Row With Moon Roof or Refer to Interior Lamp - Second Row Without Moon Roof, Third Row . No REPAIR the ground circuit for the lamp in question. - For a front interior lamp (overhead console), measure:
- O8 CHECK FOR VOLTAGE TO THE INOPERATIVE TASK LAMP
- Ignition OFF.
- Disconnect: Task Lamp.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C9049-1 Ground
Is the voltage greater than 11 volts?
Yes GO to O9. No REPAIR the demand lamp voltage supply circuit for an open. - O9 CHECK THE TASK LAMP GROUND CIRCUIT FOR AN OPEN
Is the voltage greater than 11 volts?
Yes INSTALL a new task lamp. No REPAIR the ground circuit in question. - O10 CHECK FOR CORRECT BCM OPERATION
- Disconnect the BCM connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- corrosion (install new connector or terminals - clean module pins)
- pushed-out pins - install new pins as necessary
- Reconnect the BCM connectors and make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, discontinue this test and follow TSB instructions. If no TSBs address this concern, INSTALL a new BCM. REFER to Multifunction Electronic Modules - Without Intelligent Access or REFER to Multifunction Electronic Modules - With Intelligent Access . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues. CLEAR the DTCs.
NOTE:
If the jumper wire fails, refer to the OEM ELECTRICAL WIRING DIAGRAM INTRODUCTION
to identify the possible causes of the circuit short.