Pinpoint Test G : Transmission Fluid Temperature Sensor
WARNING: This page is about a different variant/trim than selected.
- G1 RETRIEVE AND RECORD ALL DTCS
- Using the diagnostic scan tool, retrieve all DTCs.
Are DTCs P0710, P0711, P0712, P0713, P1711 and/or P1783 present?
Yes For DTCs P0710, P0712 and/or P0713, GO to G2. For DTC P0711, P1711 and/or P1783, GO to G6. No GO to Symptom Chart . - G2 CHECK THE TFT SENSOR SIGNAL INPUT
- Ignition OFF.
- Disconnect: Transmission Vehicle Harness C1520A .
- Inspect the connector for damaged or pushed-out terminals, corrosion, loose wires and missing or damaged seals.
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: TFT and TFTV PIDs.
Does the TFT PID display a temperature of -40 ° C (-39.9 ° F) and the TFTV PID display 4.9 volts?
Yes GO to G3. No REPAIR the circuit. - G3 CHECK THE TFT SENSOR SIGNAL CIRCUIT
- Connect a fused jumper wire
between.
Positive Lead Negative Lead Pin Circuit Pin Circuit C1520A-2 VET27 (BN/YE) C1520A-1 RE407 (YE/VT)
Does the TFT PID display a temperature of 191-198 ° C (376-388 ° F) and the TFTV PID display 0.0 to 0.2 volts?
Yes GO to G5. No GO to G4. - Connect a fused jumper wire
between.
- G4 CHECK THE TFT SENSOR SIGNAL VOLTAGE
- Measure the voltage
between.
Positive Lead Negative Lead Pin Circuit Pin Circuit C1520A-2 VET27 (BN/YE) - Ground
Is the voltage between 4.8 and 5.1 volts?
Yes GO to G5. No INSPECT and REPAIR the circuit. If an open circuit is not found, INSTALL a new TCM. REFER to Transmission Control Module (TCM) . PROGRAM the TCM with the latest calibration level. PERFORM the Solenoid Body Strategy Download procedure. REFER to Solenoid Body Strategy Download . - Measure the voltage
between.
- G5 CHECK THE TFT SENSOR RESISTANCE
- Measure the component side resistance
between.
Positive Lead Negative Lead Pin Circuit Pin Circuit 1 - 2 - Transmission Fluid Temperature
?C ?F Resistance (Ohms) -40 to -20 -40 to -4 1, 076K-269K -19 to -1 -3 to 31 309K-91K 0-20 32-68 104K-35K 21-40 69-104 40K-15K 41-70 105-158 17K-4.9K 71-90 159-194 5.6K-2.5K 91-110 195-230 3.0K-1.4K 111-130 231-266 1.7K-0.8K 131-150 267-302 0.97K-0.56K
Does the temperature to resistance specifications match?
Yes GO to Symptom Chart to diagnose an overheating concern. No INSTALL a new solenoid body leadframe. REFER to Solenoid Body Leadframe . - Measure the component side resistance
between.
- G6 ON DEMAND SELF TEST
- Check and make sure the transmission vehicle harness C1520A Is fully seated, the terminals are engaged in the connector and in good condition before proceeding.
- Using the diagnostic scan tool, make sure the transmission fluid temperature is between 1.1 ° C (30 ° F) and 104.4 ° C (220 ° F).
- Perform the KOER self-test.
Are DTC P0711, P1711 and/or P1783 present?
Yes For DTCs P0711 and P1711, INSTALL a new solenoid body leadframe. REFER to Solenoid Body Leadframe . For DTC P1783, REFER to Transaxle Transmission Cooling . No The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or terminal issues.