PINPOINT TEST I : The Liftgate Intelligent Access (IA) Is Inoperative
NOTE:
The Intelligent Access (IA) feature is a programmable parameter and can be enabled/disabled with a scan tool. If the feature is disabled, the Intelligent Access (IA) feature to enter the vehicle and passive starting will be inoperative. To start the vehicle, the Intelligent Access (IA) key has to be placed in the backup slot.
- I1 CHECK THE RKE OPERATION
- Press the unlock button on an Intelligent Access (IA) key.
Does the driver door unlock?
Yes GO to I2. No GO to Pinpoint Test J . - I2 CHECK THE POWER LIFTGATE OPERATION
- Press the interior power liftgate switch.
Does the power liftgate open?
Yes GO to I3. No REFER to Body Closures . - I3 CHECK THE IA KEY
- Place the Intelligent Access (IA) key on the center console and start the engine.
Does the engine start?
Yes GO to I4. No REFER to Passive Anti-Theft System (PATS) - With Intelligent Access (IA) . - I4 CARRY OUT A NETWORK TEST
- Using a scan tool, perform the network test.
Does the RFA module and LTM pass the network test?
Yes GO to I5. No REFER to Module Communications Network . - I5 RETRIEVE THE RFA MODULE DTCs FROM THE SELF-TEST
- Using a scan tool, perform the RFA module self-test.
Is DTC B113E:11 present?
Yes GO to I6. No GO to I8. - I6 CHECK THE LIFTGATE RELEASE SWITCH FOR A SHORT TO GROUND
- Disconnect: Liftgate Release Switch.
- Using a scan tool, clear the RFA module DTCs.
- Using a scan tool, perform the RFA module self-test.
Is DTC B113E:11 retrieved again?
Yes GO to I7. No INSTALL a new exterior liftgate release switch. REFER to Liftgate Release Switch . - I7 CHECK THE LIFTGATE RELEASE SWITCH INPUT CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: RFA Module C2153B.
- Measure:
Positive Lead Measurement / Action Negative Lead C4216-2 Ground
Is the resistance greater than 10, 000 ohms?
Yes GO to I17. No REPAIR the circuit. - I8 CHECK THE RFA MODULE EXTERNAL TRUNK SWITCH (Trunk_Ext_Sw) PID
- Using a scan tool, view RFA module PIDs.
- Press the liftgate release switch while monitoring the RFA module PID Trunk_Ext_Sw.
Does the PID indicate the switch is being pressed?
Yes GO to I12. No GO to I9. - I9 CHECK THE EXTERIOR LIFTGATE RELEASE SWITCH
- Disconnect: Liftgate Release Switch.
- Using a scan tool, view RFA module PIDs.
- Monitor the RFA module PID Trunk_Ext_Sw.
Does the PID indicate that the switch is being pressed?
Yes REMOVE the jumper wire. INSTALL a new exterior liftgate release switch. REFER to Liftgate Release Switch . No REMOVE the jumper wire. GO to I10. - I10 CHECK THE LIFTGATE RELEASE SWITCH GROUND CIRCUIT FOR AN OPEN
- Using a scan tool, view RFA module PIDs.
- Monitor the RFA module PID Trunk_Ext_Sw.
- Connect a fused jumper wire:
Positive Lead Measurement / Action Negative Lead C4216-2 Ground
Does the PID indicate that the switch is being pressed?
Yes REMOVE the jumper wire. REPAIR the circuit. No REMOVE the jumper wire. GO to I11. - I11 CHECK THE LIFTGATE RELEASE SWITCH INPUT CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: RFA Module C2153B.
Is the resistance less than 3 ohms?
Yes GO to I17. No REPAIR the circuit. - I12 CHECK THE LIFTGATE IA ANTENNA
- Ignition OFF.
- Disconnect: Liftgate Intelligent Access (IA) Antenna.
- Measure:
Positive Lead Measurement / Action Negative Lead (Component Side) C4082-1 (Component Side) C4082-2
Is the resistance between 0.3 and 0.6 ohms?
Yes GO to I13. No INSTALL a new liftgate IA antenna. REFER to or Liftgate Intelligent Access (IA) Antenna. - I13 CHECK THE LIFTGATE IA ANTENNA CIRCUITS FOR A SHORT TO VOLTAGE
- Disconnect: RFA Module C2153A.
- Ignition ON.
Is any voltage present?
Yes REPAIR the affected circuit. No GO to I14. - I14 CHECK THE LIFTGATE IA ANTENNA CIRCUITS FOR A SHORT TO GROUND
- Ignition OFF.
Are the resistances greater than 10, 000 ohms?
Yes GO to I15. No REPAIR the affected circuit. - I15 CHECK THE LIFTGATE IA ANTENNA CIRCUITS FOR A SHORT TO EACH OTHER
Are the resistances greater than 10, 000 ohms?
Yes GO to I16. No REPAIR the circuits. - I16 CHECK THE LIFTGATE IA ANTENNA CIRCUITS FOR AN OPEN
Are the resistances less than 3 ohms?
Yes GO to I17. No REPAIR the affected circuit. - I17 CHECK FOR CORRECT RFA MODULE OPERATION
- Ignition OFF.
- Disconnect and inspect all RFA module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all RFA module connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new RFA module. REFER to Multifunction Electronic Modules . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.