Home >> Ford >> 2015 >> Explorer Limited, 3.5L Eng VIN 8, AWD >> Repair and Diagnosis >> Accessories & Equipment >> Cruise Control Systems >> Cruise Control - Adaptive >> General Procedures >> Cruise Control Module (C-CM) (with Sensor) Adjustment

Cruise Control Module (C-CM) (with Sensor) Adjustment

General Procedure 

NOTE: In order to align the C-CM, the vehicle must be in a wheel alignment bay station so that the vehicle is level.
NOTE: Damage to the C-CM bracket may affect correct alignment. When aligning the C-CM, inspect the C-CM bracket for damage and repair as necessary before carrying out the alignment procedure.

  1. 1.

    Remove the front bumper cover. REFER to Bumpers .

  1. 2.

    Place the vehicle on a wheel alignment bay station.

  1. 3.

    Locate the C-CM radar sensor alignment screw.
GFD37192Courtesy of FORD MOTOR COMPANY

  1. 4.

    Place a combination square level on the face of the C-CM radar sensor unit and check vertical alignment.
GFD37193Courtesy of FORD MOTOR COMPANY

  1. 5.

    Keeping the combination square level on the face of the C-CM radar sensor unit, adjust the pitch of the sensor by using an E5 inverted Torx ® bit to adjust the screw until the sensor is vertical and level.
GFD37194Courtesy of FORD MOTOR COMPANY
    NOTE: Prior to installing the front bumper cover, clean and remove any debris on the front or back of the cover.

  1. 6.
    Install the front bumper cover. REFER to Bumpers .
    NOTE: The engine must be running during the scan tool horizontal calibration procedure. Failure to leave the engine running throughout the entire procedure results in the cancellation of the alignment procedure and the system remains non-functional.

  1. 7.
    Start the engine.

  1. 8.

    Follow the scan tool on-screen instructions to carry-out the CCM calibration procedure located in IDS under Toolbox > Electrical > Cruise Control > CCM Calibration

  1. 9.

    Follow the prompts to drive the vehicle after successful completion of the procedure. This may take several minutes.