DTC Chart: Generic Function Module (GFM)

Diagnostics in this article assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to Service Information

DTC Chart: Generic Function Module (GFM) 

DTC Description Action
B1457:11 Auxiliary Switch 1: Circuit Short To Ground GO to Pinpoint Test G 
B1457:15 Auxiliary Switch 1: Circuit Short To Battery or Open GO to Pinpoint Test G 
B1457:23 Auxiliary Switch 1: Signal Stuck Low GO to Pinpoint Test G 
B1458:23 Auxiliary Switch 2: Signal Stuck Low GO to Pinpoint Test G 
B1459:11 Auxiliary Switch 3: Circuit Short To Ground GO to Pinpoint Test G 
B1459:15 Auxiliary Switch 3: Circuit Short To Battery or Open GO to Pinpoint Test G 
B1459:23 Auxiliary Switch 3: Signal Stuck Low GO to Pinpoint Test G 
B145A:23 Auxiliary Switch 4: Signal Stuck Low GO to Pinpoint Test G 
B146B:12 Auxiliary Output 1: Circuit Short To Battery GO to Pinpoint Test G 
B146B:19 Auxiliary Output 1: Circuit Current Above Threshold GO to Pinpoint Test G 
B146C:12 Auxiliary Output 2: Circuit Short To Battery GO to Pinpoint Test G 
B146C:19 Auxiliary Output 2: Circuit Current Above Threshold GO to Pinpoint Test G 
B146D:12 Auxiliary Output 3: Circuit Short To Battery GO to Pinpoint Test G 
B146D:19 Auxiliary Output 3: Circuit Current Above Threshold GO to Pinpoint Test G 
B146E:12 Auxiliary Output 4: Circuit Short To Batter GO to Pinpoint Test G 
B146E:19 Auxiliary Output 4: Circuit Current Above Threshold GO to Pinpoint Test G 
U1000:00 Solid State Driver Protection Activated - Driver Disabled: No Sub Type Information The Generic Function Module (GFM) has temporarily disabled an output because an excessive current draw exists (such as a short to ground). The Generic Function Module (GFM) cannot enable the output until the cause of the short is corrected. ADDRESS all other DTCs first. After the cause of the concern is corrected, CLEAR the DTCs. REPEAT the self-test.
U3000:49 Control Module: Internal Electronic Failure The module has permanently disabled an output because an excessive current draw fault (such as a short to ground) has exceeded the limits that the Generic Function Module (GFM) can withstand. The cause of the excessive current draw MUST be corrected before a new Generic Function Module (GFM) is installed. ADDRESS all other DTCs first. After the cause of the concern is corrected, INSTALL a new Generic Function Module (GFM). Refer to Generic Function Module (GFM) .