PINPOINT TEST M : The Air Conditioning (A/C) Is Inoperative: Notes
Refer to AUTOMATIC CLIMATE CONTROL SYSTEM for schematic and connector information.
Normal Operation and Fault Conditions
When the A/C is requested, the FCIM sends the message over the I-CAN to the IPC. The IPC then sends the button press message to BCM over the HS-CAN. The BCM then sends the button press message to the HVAC module over the MS-CAN. Lastly, the HVAC module sends an A/C request message through the MS-CAN to the BCM and the BCM sends the A/C request through the HS-CAN to the PCM.
Refer to CLIMATE CONTROL - DATC , Control System Logic
Refer to CLIMATE CONTROL - DATC , Controls and Compressor Cycling
When an A/C request is received by the PCM, the A/C compressor clutch only engages through the A/C clutch relay if all of these conditions are met:
- The PCM does not detect excessively high or low refrigerant pressure from the A/C pressure transducer.
- The PCM does not detect excessively high engine coolant temperature.
- The PCM does not detect an ambient air temperature below -1°C (30.2°F).
- The PCM has not detected a WOT condition.
- The HVAC module does not detect an evaporator discharge air temperature below 0°C (32°F).
Possible Sources
- Fuse
- Wiring, terminals or connectors
- A/C system discharged/low charge
- PCM
- HVAC module
- FCIM
- Evaporator temperature sensor
- A/C pressure transducer
- A/C compressor
- A/C clutch relay
- A/C compressor clutch air gap
Visual Inspection and Diagnostic Pre-checks
- Inspect the BJB fuse 62 (10A).
- Inspect the A/C clutch relay.
- Inspect for A/C system discharged/low charge.