Receiver Drier Cartridge - 3.5L Ti-VCT: Removal
WARNING:
Before beginning any service procedure in this service information, refer to SAFETY WARNINGS
NOTE:
Installation of a new receiver/drier desiccant bag is not required when repairing the A/C system, except when there is physical evidence of contamination from a failed A/C compressor or damage to the receiver/drier desiccant bag. Damage to the receiver/drier desiccant bag includes physical damage to the receiver/drier desiccant bag or moisture contamination. Moisture contamination results only from a complete loss of refrigerant and equalization of the refrigerant system pressure with atmospheric pressure for a period longer than one hour. If even a slight amount of positive refrigerant pressure is present in the system before repairs are carried out, the receiver/drier desiccant bag should not be replaced.
- 1.
Recover the refrigerant. Refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging .
- 2.
Measure the diameter of the access hole. If the measurement is less then 40mm proceed to step 3. If the measurement is 40mm or greater proceed to step 4.
- 3.
Remove 3.0 mm (0.118 in) of material from the inboard and front of the opening utilizing a rotary tool.