Generator Current Sensor: Installation
- 1.NOTE: The generator current sensor must be installed in the proper position and orientation to function correctly.
With the generator current sensor tape tab pointing upward, position the generator current sensor to the index-mark on the battery cable and secure with electrical tape.
- 4.
Connect the generator B+ terminal and install the nut. Position the generator B+ terminal cover.- 1.
Tighten to 17 Nm (150 lb-in).
- 1.
- 5.
Connect the battery. Refer to Battery Disconnect .