LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2015 >> Explorer Limited, 3.5L Eng VIN 8, AWD >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Engine Controls - Powertrain DTC Charts & Descriptions (Except Diesel & Hybrid) >> Diagnostic Trouble Code (DTC) Charts and Descriptions >> P1001 - Key On Engine Running (KOER) Not Able To Complete, KOER Aborted - DTC Chart

P1001 - Key On Engine Running (KOER) Not Able To Complete, KOER Aborted - DTC Chart

P1001 - KEY ON ENGINE RUNNING (KOER) NOT ABLE TO COMPLETE, KOER ABORTED - DTC CHART

Description:  This non-malfunction indicator lamp (MIL) DTC sets when the KOER self-test does not complete in the time allowed.
Possible Causes: 
  • Incorrect self-test procedure
  • Unexpected response from the self-test monitors
  • RPM out of specification
Diagnostic Aids:  Carry out the KOEO self-test. Refer to GO to Pinpoint Test QT .
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All Refer to the Description, Possible Causes and Diagnostic Aids for the DTC.