PINPOINT TEST C : The AC Power Point Turns Off After 13 Minutes
- C1 RETRIEVE BCM-B DTCs
- Connect the scan tool.
- Ignition ON.
- Using a scan tool, perform BCM-B self-test to retrieve DTCs.
- Record any BCM-B DTCs retrieved.
Is U0100:00 present in the BCM-B ?
Yes Go to Pinpoint Test K to diagnose the BCM-B DTC. No GO to C2. - C2 CHECK THE LIN COMMUNICATION CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect BCM-B C2280B.
- Disconnect DC /AC Inverter C3501A.
- Measure:
Positive Lead Measurement / Action Negative Lead C3501A-5 Ground
Is the resistance greater than 10, 000 ohms?
Yes GO to C3. No REPAIR the circuit. - C3 CHECK THE LIN COMMUNICATION CIRCUIT FOR AN OPEN
Is the resistance less than 5 ohms?
Yes INSTALL a new DC /AC inverter. Refer to Direct Current/Alternating Current (DC/AC) Inverter . TEST the system for normal operation. If the AC outlet still turns off after 13 minutes when the engine is running, INSTALL a new BCM-B. REFER to Multifunction Electronic Modules (With Intelligent Access (IA)) or REFER to Multifunction Electronic Modules (Without Intelligent Access (IA)). No REPAIR the circuit.