P0118 - Engine Coolant Temperature (ECT) Sensor 1 Circuit High - DTC Chart
P0118 - ENGINE COOLANT TEMPERATURE (ECT) SENSOR 1 CIRCUIT HIGH - DTC CHART
| Description: This DTC sets when the ECT sensor signal is greater than the self-test maximum. The ECT sensor signal maximum is -50° C (-58° F). | |||
Possible Causes:
|
|||
| Diagnostic Aids: A concern is present if the ECT (TEMP) PID reading is less than -50° C (-58° F) with the ignition ON engine OFF or during any engine operating mode. | |||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test DX . | ||