P1013 - WASTEGATE Control Pressure Circuit High - DTC Chart
P1013 - WASTEGATE CONTROL PRESSURE CIRCUIT HIGH - DTC CHART
| Description: This DTC sets when the wastegate vacuum sensor reading is greater than a calibrated threshold and the fault timer has exceeded the calibrated time threshold indicating an open circuit or a short to voltage. | |||
Possible Causes:
|
|||
| Diagnostic Aids: The typical maximum threshold is 4.93 V and time threshold is 5 seconds. | |||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test HN . | ||