Pinpoint Test Aw : U0151:00
- AW1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify there is an observable symptom present.
Is an observable symptom present?
Yes GO to AW2. No The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition. - AW2 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Using a scan tool, perform a network test.
- Carry out the network test.
Does the RCM pass the network test?
Yes GO to AW3. No REFER to Module Communications Network . - AW3 RETRIEVE THE RECORDED DTCs FROM THE RCM SELF-TEST
- Using a scan tool, perform the RCM self-test.
Is DTC U3003:16 or DTC U3003:17 recorded?
Yes REFER to Supplemental Restraint System . No GO to AW4. - AW4 RETRIEVE THE RECORDED DTCs FROM THE IPC SELF-TEST
- Using a scan tool, perform the IPC self-test.
Is DTC U3003:16 or DTC U3003:17 recorded?
Yes For DTC U3003:16, GO to Pinpoint Test BD . For DTC U3003:17, GO to Pinpoint Test BE . No GO to AW5. - AW5 RECHECK THE IPC DTCs
- Clear the DTCs.
- Wait 10 seconds.
- Repeat the IPC self-test.
Is DTC U0151:00 still present?
Yes GO to AW6. No The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition. - AW6 CHECK FOR DTC U0151:00 SET IN OTHER MODULES
- Clear all DTCs.
- Ignition OFF.
- Ignition ON.
- Wait 10 seconds.
- Using a scan tool, perform self-test.
- Retrieve the continuous memory DTCs from all modules.
Is DTC U0151:00 set in the OCSM ?
Yes INSTALL a new RCM. REFER to Supplemental Restraint System . No Refer to IPC Hardware Testing .