PINPOINT TEST R : The Ambient Lighting Does Not Cycle Through All Color Combinations
- R1 CHECK THE AMBIENT LIGHTING HARNESS
- Ignition OFF.
- Disconnect: HVAC Module C228C.
- Diode check:
Positive Lead Measurement / Action Negative Lead C228C-5 C228C-17 C228C-6 C228C-17 C228C-7 C228C-17
Does the meter indicate the circuit is good?
Yes GO to R2. No REPAIR the circuit in question or INSTALL a new ambient lighting harness as necessary. - R2 CHECK FOR CORRECT HVAC MODULE OPERATION
- Disconnect and inspect all HVAC module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the HVAC module connectors and make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new HVAC module. REFER to Climate Control DATC . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.