PINPOINT TEST M : A Single Power Window is Inoperative - LH Front, Base
- M1 CHECK THE LH FRONT WINDOW CONTROL SWITCH GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: LH Front Window Control Switch C535B .
- Measure:
Positive Lead Measurement / Action Negative Lead C535B-1 Ground
Is the resistance less than 3 ohms?
Yes GO to M2. No REPAIR the circuit. - M2 CHECK THE LH FRONT WINDOW CONTROL SWITCH OPERATION
- Ignition ON.
- To check upward window operation, connect fused jumper wires:
Positive Lead Measurement / Action Negative Lead C535B-3 C535B-4 C535B-2 C535B-1
- To check downward window operation, connect fused jumper wires:
Positive Lead Measurement / Action Negative Lead C535B-3 C535B-2 C535B-4 C535B-1
Does the window move up and/or down?
Yes INSTALL a new LH front window control switch. Refer to Window Control Switch . No GO to M3. - M3 CHECK FOR AN OPEN CIRCUIT BETWEEN THE LH WINDOW CONTROL SWITCH AND WINDOW MOTOR
- Ignition OFF.
- Disconnect: LH Front Window Motor C540 .
Are the resistances less than 3 ohms?
Yes INSTALL a new LH front window motor. Refer to Window Regulator Motor - Front Door . No REPAIR the affected circuit.