PINPOINT TEST A : The Power Liftgate Is Inoperative: Notes
Refer to Power Liftgate for schematic and connector information.
Normal Operations and Fault Conditions
The LTM receives battery voltage at all times through the BCM fuse 9 (10A) and BJB fuse 7 (30A). The LTM has a dedicated ground circuit.
Refer to Body Closures for a detailed description on power liftgate operation.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1179 | Latch Motor Circuit Short to Battery | A continuous memory and on-demand DTC that sets when the LTM detects a short to voltage on the latch motor circuit(s) for more than 1 second. |
| B117A | Latch Motor Circuit Short to Ground | A continuous memory and on-demand DTC that sets when the LTM detects a short to ground on the latch motor circuit(s) for more than 1 second. |
| B117B | Latch Motor Circuit Open | A continuous memory and on-demand DTC that sets when the LTM detects an open on the latch motor circuit(s). The LTM determines the circuit(s) is open when it detects no current change upon latch motor activation. |
| B2552 | Vbatt 2 Circuit Open | A continuous memory and on-demand DTC that sets when the LTM detects less than 4 volts on the high current voltage feed circuit and the logic voltage feed circuit is greater than 8 volts. |
| B2819 | Gate Motor Circuit Short to Battery | A continuous memory and on-demand DTC that sets when the LTM detects a short to battery on the power liftgate motor circuit(s) for more than 1 second. |
| B2936 | Gate Motor Open | A continuous memory and on-demand DTC that sets when the LTM detects an open on the power liftgate motor circuit(s). The LTM determines the circuit(s) is open when it detects no current change upon liftgate motor activation. |
| B2937 | Gate Motor Short to Ground | A continuous memory and on-demand DTC that sets when the LTM detects a short to ground on the power liftgate motor circuit(s) for more than 1 second. |
Visual Inspection and Diagnostic Pre-checks
- BCM fuse 9 (10A)
- BJB fuse 7 (30A)