Diagnostic Test

PERFORM THE A/C COOL-DOWN TEST 

  1. The following conditions must be met before running the A/C Cool-Down test.
    • No Powertrain Control Module (PCM) DTCs present.
    • No Communication DTCs present.
    • Condenser cooling fan working properly.
    • No active HVAC evaporator temperature sensor, sun sensor, recirculation, mode, or blend door actuator DTCs present.
    • The refrigerant system must be fully charged.
    • The blower motor must operate correctly in all speeds.
    • The evaporator temperature must be above 12.7°C (55°F).
    • The A/C compressor must be turned off.
    • Blower must be on high.
  2. With the scan tool, perform the A/C Cool-Down Test.

    Did the test pass?

    Yes 

    No 

    • Perform the A/C PERFORMANCE procedure. Refer to DIAGNOSIS AND TESTING . Run the Cool-Down Test after any repairs are performed.