LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 2021 >> Voyager LX, Gas >> Repair and Diagnosis >> Transmission >> Automatic Trans >> 948TE/9HP48 Automatic Transmission (Service Information) >> Clutch, E >> Adjustments >> E-Clutch Measurement

E-Clutch Measurement

After the E-clutch is cleaned and assembled the end play must be measured to verify that the correct select snap-ring has been installed.

GC0173279Courtesy of CHRYSLER GROUP, LLC
  1. Place the E-clutch assembly on a suitable arbor press. Mount a dial indicator with magnetic base (2) attached to the E-clutch retainer (1) with the plunger tip (3) resting on the reaction plate (4).
  2. Pry up on the bottom of the reaction plate (4) and zero the dial indicator.
    GC0173342Courtesy of CHRYSLER GROUP, LLC
  3. Place the (special tool #10429, Gauge, Force) (2), (special tool #8901A, Pressing Tool) (with press scale removed) and (special tool #10428, Adapter, Pressing Tool) (3) on the reaction plate (5).
  4. Using an arbor press (1), apply 20.4 kg (45 lbs) of force (which corresponds to a 45 psi gauge reading) to compress the E-clutch and record the dial indicator (4) measurement.
  5. The reading should be within specification. Refer to TECHNICAL SPECIFICATIONS . If not, install a thicker or thinner E-clutch select snap-ring.