Feeler Gauge
- Slide a snug-fitting feeler gauge between the connecting rod and crankshaft journal flange. Compare the measured side clearance to the. Refer to TECHNICAL SPECIFICATIONS .
- Repeat this procedure for each connecting rod. Rotate the crankshaft for connecting rod accessibility.