Housing - Air Inlet: Installation
- If required, install the recirculation-air door and recirculation door actuator to the air inlet housing. Tighten the screws securely.NOTE:
If the foam seal on the top of the inlet housing is deformed or damaged, the seal must be replaced.
- Position the air inlet housing (3) to the top of the HVAC housing.
- Install the screws (1) that secure the air inlet housing to the HVAC housing. Tighten the screws securely.
- Connect the recirculation door actuator wire harness connector.
- Install the HVAC housing. Refer to HOUSING, HVAC, REMOVAL AND INSTALLATION .