Removal And Installation: Bank-2-Solenoid-1: Removal
- Remove the upper intake manifold. Refer to MANIFOLD, INTAKE, REMOVAL AND INSTALLATION .
- Disconnect the wire harness connector (1) from the Variable Valve Lift (VVL) solenoid.
- Remove the retaining bolt (2) from the VVL solenoid.
- Remove the VVL solenoid from the cylinder head cover.
- The O-ring seal can be reused if not damaged.