Door Flushness Adjustment
- Check sliding door flushness at the C-pillar striker.
- If necessary, loosen the bolts (2) and slide the striker (1) in or out to achieve desired flush measurement. Refer to GAP AND FLUSH DIMENSIONS .
- Tighten the bolts (2) to the proper specification. Refer to TECHNICAL SPECIFICATIONS .
- Check upper B-pillar flushness to A-pillar cover.
- Open the door to mid-point of travel.
- Mark the outline of upper roller arm on the door to assist in making adjustments.
- Loosen the bolts attaching upper roller arm to door.
- Add shim to increase gap.
- Tighten the upper roller arm bolts to the proper specification. Refer to TECHNICAL SPECIFICATIONS .
- Check lower B-pillar flushness to A-pillar cover.
- If necessary, loosen the bolts (1) and slide the striker (2) in or out to achieve desired flush measurement. Refer to GAP AND FLUSH DIMENSIONS .
- Tighten the bolts (1) to the proper specification. Refer to TECHNICAL SPECIFICATIONS .