PINPOINT TEST A : The Power Liftgate Is Inoperative
- A1 CHECK THE OPERATION OF THE POWER LIFTGATE SWITCHES
- Vehicle in park.
- Close the liftgate to the full closed position (manually, if necessary).
- Activate the power liftgate from the power liftgate control switch (instrument panel).
- Activate the power liftgate from an RKE transmitter.
- Activate the power liftgate from the exterior liftgate switch.
Does the power liftgate power open from any switch?
Yes GO to Pinpoint Test B . No GO to A2. - A2 RETRIEVE THE DTCs FROM THE LTM
- Retrieve the recorded LTM DTCs from the self-test.
Are any LTM DTCs recorded?
Yes For DTC B2552, GO to A3. For DTC B1179, B117A, B117B, B2936, B2819 or B2937, GO to A7. For all other LTM DTCs, Refer to the LTM DTC Chart . No GO to A3. - A3 CHECK FOR VOLTAGE TO THE LTM
- Ignition OFF.
- Disconnect: LTM C4174A.
Are the voltages greater than 11 volts?
Yes GO to A4. No VERIFY BCM fuse 9 (10A) or the BJB fuse 7 (30A) is OK. If OK, REPAIR the circuit in question for an open. If not OK, REFER to the OEM ELECTRICAL WIRING DIAGRAM INTRODUCTION to identify the possible causes of the circuit short. - A4 CHECK THE LTM GROUND FOR AN OPEN
- Measure:
Positive Lead Measurement / Action Negative Lead C4174A-1 Ground
Is the resistance less than 3 ohms?
Yes RECONNECT the LTM and GO to A5. No REPAIR the circuit. - Measure:
- A5 CHECK THE DETENT AND FORKBOLT SWITCH PIDs
- Using a scan tool, view the LTM PIDs.
- Operate the liftgate manually while monitoring the LTM PIDs :
- Detent Switch Status (DETENTSW)
- Forkbolt Switch Status (FORKBLT_S)
- Forkbolt Secondary Switch (FKSWSEC)
- Begin with the liftgate in the open position, then slowly close the liftgate into each of the latch positions specified.
Liftgate Latch Position DETENTSW FORKBLT_S FKSWSEC Fully unlatched Inactive Active Active Primary Active Inactive Inactive
Do the switch states agree with the table?
Yes GO to A6. No GO to Pinpoint Test L . - A6 CHECK THE OPTICAL SENSOR 1 (OPT_SEN_1) AND 2 (OPT_SEN_2) STATUS PIDs
- Open the liftgate to the full OPEN position.
- Using the scan tool, view LTM PIDs.
- Monitor the LTM PIDs OPT_SEN_1 and OPT_SEN_2 while slowly closing the liftgate.
Do both of the PID values alternate from ACTIVE to INACTIVE while the liftgate is moving?
Yes GO to A7. No GO to Pinpoint Test K . - A7 CHECK THE MOTOR AND LATCH CIRCUITS FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: LTM C4174A.
- Disconnect: Power Liftgate Motor.
- Disconnect: Power Liftgate Latch.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C4174A-2 Ground C4174A-3 Ground C4174A-5 Ground C4174A-6 Ground
Is any voltage present?
Yes REPAIR the circuit in question. No GO to A8. - A8 CHECK THE MOTOR AND LATCH CIRCUITS FOR A SHORT TO GROUND
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C4174A-2 Ground C4174A-3 Ground C4174A-5 Ground C4174A-6 Ground
Are the resistances greater than 10, 000 ohms?
Yes GO to A9. No REPAIR the circuit in question. - A9 CHECK THE MOTOR AND LATCH CIRCUITS FOR AN OPEN
- For the power liftgate motor, measure:
Positive Lead Measurement / Action Negative Lead C4174A-5 C4223-1 C4174A-6 C4223-4
- For the power liftgate latch, measure:
Positive Lead Measurement / Action Negative Lead C4174A-2 C4819-5 C4174A-3 C4819-7
Are the resistances less than 3 ohms?
Yes GO to A10. No REPAIR the circuit in question. - For the power liftgate motor, measure:
- A10 CHECK THE UNLATCH OPERATION
- Connect: Power Liftgate Latch.
- Close and latch the liftgate.
- Momentarily connect a fused jumper wire:
Positive Lead Measurement / Action Negative Lead C4174A-3 C4174A-4 C4174A-2 C4174A-1
Does the unlatch/cinching motor activate?
Yes LEAVE the liftgate unlatched, GO to A11. No INSTALL a new power liftgate latch. REFER to Handles, Locks, Latches and Entry Systems With Intelligent Access (IA) . - A11 CHECK THE POWER LIFTGATE MOTOR OPERATION
- Connect: Power Liftgate Motor.
- Place the liftgate in the fully closed and unlatched position.
- Momentarily connect a fused jumper wire:
Positive Lead Measurement / Action Negative Lead C4174A-5 C4174A-4 C4174A-6 C4174A-1
Does the power liftgate motor operate?
Yes GO to A12. No INSTALL a new power liftgate motor. Refer to Power Liftgate Motor . - A12 CHECK FOR CORRECT LTM OPERATION
- Ignition OFF.
- Disconnect and inspect all LTM connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all the LTM connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new LTM. Refer to Liftgate/Trunk Module (LTM) . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.